Yes. For reasons of homeowner safety and proper system installation, APsystems requires installation by a professional solar installer. These installers are aware of safety requirements, codes and standards, are licensed and bonded to work on electrical systems and roofs, and are trained to use APsystems equipment. Even if you’re savvy with electrical equipment, electrical code issues, if improperly addressed, could result in serious damage to person or property.
APsystems’ policy requires professional installation in order to set up an EMA monitoring account, and to service or troubleshoot the system. See our policy on DIY installations here.

Contact your original solar installer. They can help resolve your issue, whether it is a log-in problem, a production issue or hardware. They are licensed and certified for troubleshooting and, if needed, replacing our product. If they need additional support they will contact us. If your solar installer is no longer available, we can refer you to an experienced installer in your area.

Your system settings are defined as per grid and code requirements and should only be changed in rare circumstances. For example, if your system is located in an area where the grid performance is unstable, the parameters can be adjusted to tolerate the grid’s instability. If you experience such issues with the grid in your area, please contact your solar installer. They have the ability to adjust the necessary parameters of your system.

No. APsystems sells exclusively through a network of authorized distributors who sell to professional solar installers.

You will need to contact a professional solar installer to troubleshoot your system. They will work with us to determine the cause and fix the issue and, if needed, replace any defective units. Often times, troubleshooting requires electrical work or work on the roof. APsystems requires homeowners to work with a professional solar installer to resolve system issues for reasons of safety and liability.

Upon initial set up of your solar array, your installer will create your account in the EMA and provide you with log-in credentials to view your energy production. Simply download the EMA APP available in the App Store or access the EMA portal online at apsystemsema.com and enter the user name and password provided by your installer.

For every PV system powered by APsystems microinverters, monitoring is available for end-user when the PV system is hooked-up with an ECU (Energy Communication Unit) connected to the internet at home. Using the EMA APP or the EMA web portal, the end-user can monitor the performance of their system on a daily /monthly / yearly basis even when they are not at home.

You will need to contact your solar installer to have your account set up. They have the ability to create and update system owner accounts for their customers. If they are not responsive or no longer in business, contact APsystems technical support in your region.

Micros

The UID (Unique IDentifier) or serial number is a unique 12 digit number assigned to all microinverters.

The modules can work with microinverters as long as the voltage and current are not exceeding. Larger power modules will not damage. Normally it is recommend to have DC/AC around 1.3. APsystems provides module compatibility calculator via our online  compatibility calculator which can be found by visiting our library.

Contact your installer who can provide all the specs and information on the products used in your solar array. They can and typically do work with the inspectors on your behalf.

To view specifications, visit our library.

Absolutely, APsystems has done HALT testing which includes; damp heat, humidity freeze, salt mist and UV.

Both DS3 series and QT2 series are compliant with local regulations regarding RPC.

Yes, APsystems strongly recommends to install a whole-house surge protection device at the dedicated meter box. Please check with you local regulations and your professional installer.

No, APsystems does not offer an off-grid product at this time. All APsystems products comply with IEEE-1547 anti-islanding standard.

EMA

First visit apsystemsema.com and see if the EMA portal is down for servicing or updating. If you are still unable to log in after 24 hours, contact your installer to help reset / change your user name, email address or your login password.

Visit apsystemsema.com and click the „Lost your password?” link. You will need to know your user name.

Contact your installer to help reset / change your user name, email address or your login password. They have access to create and update system owner accounts.

Fill out the warranty transfer document form here and email it to APsystems support in your region (see your regional APsystems website for local contact info) and one of our support agents will set up EMA access for the new homeowner.

No, nothing is wrong with your inverter. The power output of the module is typically +/- 10% from module to module. In addition, the ECU gateway 'polls’, or asks, the inverters for their power production every five minutes one-by-one, and the polling time may differ by a few minutes per solar panel so variations will happen from time-to-time.

The APsystems ECU gateway collects a snapshot of data from each microinverter on the DC side every five minutes during operation and was not designed to be a highly accurate revenue-grade meter (RGM). The utility company utilizes a revenue grade meter which constantly measures power production on the AC side and as such collects data in real-time. The EMA is intended to demonstrate power production, not record revenue grade data. The energy production numbers shown in the EMA are an estimate based on these infrequent intervals and will often be different than those shown in your utility bill for reasons of monitoring frequency, accuracy and what’s being measured (AC vs DC).

In case of one or more panels is showing NC, a few checks can be done: 1. Make sure the ECU has connected to the power; 2. Make sure the UID of microinverters have been entered to the ECU correctly; 3. Wait for enough time. It takes around 10 minutes. when there are more microinverters, it takes more than 30 minutes; 4. Make sure the light on the microinvertr is green; 5. Make sure the ECU is close to Microinverters. If all of the above doesn’t work, please contact our customer support team.

Verify that the AC breakers are in the on position, and power is connected all the way to the end of each branch circuit and that panels are clean. We do not recommend homeowners do electrical work or climb up onto the roof. We highly recommend you contact a professional solar installer to troubleshoot and repair any issues with your system.

Yes, the login information is the same.

ECU

The UID or serial number is located on the back or side of the device and is a 12 digit number starting with '2′.

Krok 1: Włącz ECU

Krok 2: Naciśnij przycisk AP na ECU

Krok 3: Zeskanuj kod QR poniżej, by pobrać ECU Manager jeśli jeszcze tego nie zrobiłeś

Krok 4: Otwórz ECU Manager, kliknij“Dostęp lokalny” w prawym dolnym rogu

Krok 5: Połącz się z siecią WIFI ECU za pomocą ECU ID (numer użytkownika), wpisz hasło: 88888888 aby zalogować się do ECU

Uwaga: Jeżeli nie możesz znaleźć sieci WIFI ECU, proszę spróbuj ponownie. Należy umieścić ECU blisko routera. Nazwa sieci WIFI jest taka sama jak pierwszy UID (numer użytkownika) podany z tyłu ECU

Krok 6: Wróc do aplikacji ECU Manager, kliknij „Obszar roboczy” i wybież „Sieć ECU”

Krok 7: Wybierz dostępny router WIFI by połączyć się bezprzewodowo

Jeżeli połączenie zostanie nawiązane, obie diody LED na ECU zaczną świecić się na zielono.

Please follow these guidelines.

The ECU-R and ECU-C can be connected to the internet via hardwire ethernet cable or Wi-Fi connection. If utilizing the hardwire ethernet cable (the preferred and most reliable method) simply connect the Ethernet port on the ECU-R or ECU-C to an open Ethernet port on your router or switch. If utilizing the built-in Wi-Fi, access the ECU APP and navigate to the Settings tab, WLAN and search for available Wi-Fi, pick your router, enter the password and hit okay. See our YouTube video on the ECU-R for instructions on how to do this. (note: The ECU APP also functions with the ECU-C)

Yes, the ECU has an offline monitor function (traditionally used by installers) that can be used for customers that do not have internet. The offline monitoring feature can be accessed by holding the AP button on the side of the ECU for approximately two seconds and then releasing, connecting your hand phone via the Wi-Fi (ECU-R_216xxxx) broadcast by the ECU and then opening the EMA Manager APP – navigating to the Data tab to see Real Time Data, Power and Energy. (Note about limited memory – check with installer today). Note: APsystems always recommends that the ECU be connected to the internet (hardline or GSM router) to ensure that the ECU and inverters can be updated to the latest software and firmware for the lifetime of the system.

It can connect to max 100 microinverters. We recommend to connect 80 microinverters for the optimized performanced. Try to position the ECU close to the microinverters and try to avoid obstacles or other electrical equipment.

Yes, you can avoid power grid reinjection/exporting by having your installer configure the ECU-C with the Zero Export function.

Move the screen from direct sunlight, reboot and observe. If that does not fix it, please contact your original solar installer.

The -W or -Web means that the ECU does not have a proper internet connection. You may have an internet outage, or have recently changed your internet ISP, router, or other network settings. Please reboot the ECU, change the cable or check the internet connection. If that does not fix it, please contact your original solar installer.

The ECU-R is a basic monitoring gateway, while the ECU-C has advanced functions; metering function, zero export and redundant energy control.

No, there is no local web access to the ECU-R

APP

EMA APP is designed for APsystems microinverters system owners and DIY users.

The EMA Manager Manager APP is a tool for professional installers to use in the initial set up of your system.

MISC

To be eligible for the warranty, APsystems microinverters need to be monitored via the EMA portal.

Please refer to our warranty T&Cs available on emea.APsystems.com

Detailed warranty policy can be found by visiting our library.

The acronym UID mean Unique IDentifier, or simply serial number.

Fill out the warranty transfer document here and email it to APsystems support in your region (see your regional APsystems website for local contact info) and one of our support agents will set up EMA access for the new homeowner. If you do not know the new homeowner’s information, fill out your information in the form and provide it to the new owners for them to complete and submit to APsystems.

Typical system sizing does not eliminate your monthly bill, just reduces your consumption from your utility. Please review your consumption month-by-month for the past year and compare your current bill to your historical bill to see consumption reduction.

The APsystems microinverter product you have installed on your roof is what is called a 'grid-tied’ inverter and needs to sense the grid to produce power. When solar energy is produced, it is described as „use it or lose it” which means it must be immediately consumed by the energy needs of the home or exported to the grid and it cannot be saved for later unless you store it in an energy storage system. If you need power for use when the AC utility power goes out, consider adding energy storage to your home energy portfolio.

Unfortunately, this happens from time-to-time. There are many qualified solar installers in your area, please reach out to them first to help you resolve your issue. We can provide them with the information they need to be successful with our equipment. If you still cannot find a replacement installer in your area, send an email to your local support team and a customer satisfaction agent will respond with certified APsystems installers in your area that will be able to assist you.

APsystems inverters are agnostic and will function perfectly with all AC coupled storage solutions on the market today. You can use our APsystems Storage Solution storage systems.

APsystems’ microinverters are designed to be grid-tied only. APsystems does not support using microinverters in conjunction with a generator on a closed-loop system. The APsystems warranty policy clearly states that microinverters use with a generator are not covered.

The API is only available for certain installers to develop their applications. The API is a REST API and delivers data in JSON format via HTTPS. The API is categorized into two-level data:
• System Details API
• ECU-level Data API
Access to the API will require unique user credentials provided by APsystems on a case-by-case basis. Contact your APsystems representative for more information.
Current calls are as follows:
• Current Power
• Daily Production
• Monthly Production
• Yearly Production
• Lifetime Production

No, the APsystems microinverters are designed to work with todays solar PV modules, not wind turbines.